System specifications
- Project: 500LPH double stage reverse osmosis filtration plant all SS304 tanks and pipelines
- Processing capacity: 500L/H
- Desalination rate: ≥99.9%
- Revovery rate: 50%-75%
- Raw water: river water, TDS: 1200ppm
- Product water: High purity sterile water for pharmaceutical/electrics industry, TDS: ≤1ppm
- Pretreatment: Sand filter+carbon filter+scale inhibitor+1um micron filter
- RO module: 4*Vontron ULP21-4040+2*Dow LCLE-4040 membrane+Dongda D500 EDI+UV sterilizer
- Valve: Runxin timer automatic
- Controller: Preset program
- Power consumption: 3.25KW max
Feed water limits
- Max operating pressure: 600psi(4.13Mpa)
- Temperature: 5-45°C (113°F)
- Max chlorine concentration: 0.1mg/L
- Max feed flowrate: 3.6 m3/hr(16.0gpm)*4
- Max feed turbidity: 1.0 NTU
- Max feed SDI (15 minutes): 5.0
- Feed pH range ( nominal): 3.0-10.0